Product Details:
Weight | 40Kg |
Airflow | 1 m3 |
Power Source | Electronic |
Voltage | 220 kv |
Country of Origin | Made in India |
Flow Rate: | 0.9 – 1.4 m3 /min free flow |
Particle Size: | Particles of 10 microns & below collected on Filter Paper holder. SPM bigger than 10 microns collected in a separate sampling bottle under the cyclone |
Sampling Time: | 28 hours (maximum) |
Sampling Time Record: | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Power requirement: | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight: | 430 x 320 x 930 mm, 45 Kg |
Automatic Sampling: | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval. |
Additional Information:
Flow Rate: | Free flow (with flow stabilization disabled) > 1.3 m3 /min. 1.0 m3 /min with Filter Paper installed and Flow Controller enabled |
Flow Rate Control: | The system will automatically maintain the flow rate constant and compensate for dust load deposited on the filter. When the dust load increases beyond the capacity of the blower the flow rate will begin to decrease and the system will automatically be shutdown if the flow rate tends to drop below 0.85 m3 /min |
Particle Size: | Particles of 10 microns & below collected on Filter Paper holder. SPM bigger than 10 microns collected in a separate sampling bottle under the cyclone |
Sampling Time: | 28 hours (maximum) |
Sampling Time Record: | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Power requirement: | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight: | 400 x 300 x 650mm., 60Kg |
Automatic Sampling: | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Weight | 40kg |
Airflow | 1m3 |
Power Source | Electronic |
Voltage | 220 kv |
Country of Origin | Made in India |
Flow Rate: | Free flow (with flow stabilization disabled) > 1.3 m3 /min. 1.0 m3 /min with Filter Paper installed and Flow Controller enabled |
Flow Rate Control: | The system will automatically maintain the flow rate constant and compensate for dust load deposited on the filter. When the dust load increases beyond the capacity of the blower the flow rate will begin to decrease and the system will automatically be shutdown if the flow rate tends to drop below 0.85 m3 /min |
Particle Size: | Particles of 10 microns & below collected on Filter Paper holder. SPM bigger than 10 microns collected in a separate sampling bottle under the cyclone |
Sampling Time: | 28 hours (maximum) |
Sampling Time Record: | 0 to 9999.99 hrs. recorded on a Time Totalizer |
Power requirement: | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight: | 400 x 300 x 650mm., 60Kg |
Automatic Sampling: | 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval. |
Additional Information:
Suction Pump: | Built-in Rotary vane type. |
Sampling Rate: | 0.5 – 1 LPM |
Timer: | 3 digit display in minutes ; Adjustable from 0 to 12 hrs. |
Running Time: | 1 – 999 Min. |
Delay Time: | 1 – 99 Min. |
Power Supply: | 230+/-10V AC, 50Hz with Battery charger and Rechargeable Batteries(2AH). |
Operation Time: | 10 hours with full charge, with sampling rate of 1 LPM. |
Charging Time: | 15 hours or less. |
Sampling Train: | Consisting of 2 nos., 35 ml glass impingers kept in ice tray connected with inert Silicone tubing. |
Additional Information:
With the addition of Benzene in petrol, in place of a lead compound, Benzene and its derivatives are now an integral part of vehicular pollution and have become a matter of concern. Unfortunately a majority of these compounds are highly toxic and many have been reported to be carcinogenic. Organic compounds are also reported to be pre-cursers for Ozone formation and play a role in secondary formation of oxidants. As such air pollution monitoring networks are now beginning intensive efforts for monitoring of specific organic compounds such as Benzene, Toluene & Xylene and often a mixture of Total Non Methane Hydrocarbons.
The APM 856 Organic Vapour Sampler meets all important requirements for field measurements of gaseous organic pollutants in ambient air. It collects samples of organic compounds by adsorbing them on an activated charcoal column. The organics are then desorbed and analyzed via a gas chromatograph to estimate the actual concentration in ambient air.
Special Features:
Additional Information:
Detector: | PID: Levels: 0.1 ppm to 0.01 ppm for hydrocarbons sensitive to PID, or FID: Levels: 0.5 ppm to 0.1 ppm for hydrocarbons sensitive to FID cycle time 1 to 10 min |
Range: | 0 - 1000 ppm for FID, 0- 100 ppm for PID |
Reproducibility: | <1% of FS |
GC specification: | Loop 0.075 to 2 ml, 10 port valve Synspec, analytical column 2 -13 m backflush column 0.5 to 2 m |
Dimensions: | 19” rack, 3 standard Height Units, depth 37.2 cm net, weight 12 Kgs |
Calibration: | Internal calibration switch for calibration with zero and span gas, gas stream required 25 ml at ambient pressure |
Consumption of gas: | PID / FID: nitrogen, quality 5.0, 2.0 bar, 5 ml/min FID: instrument air: dry and clean, 2.5 bar, 250 ml/min FID: hydrogen, quality 5.0, 2,5 bar at 20 ml/min |
Power demand: | 220 V AC, 200 VA (110 V AC available) |
Included hardware: | Computer Pentium class, harddisk >20 Gb, 6 “ full colour LCD display, I/O 2 x RS232, 4 x USB, Ethernet, PS2 keyboard/mouse, Touchscreen |
Approvals: | CE approval for EMC conformity: EN 61010-1, EN 61000-6-2 and EN 60111-6-3 |
Included software: | Windows98, GC software, TWA calculation modules, alarm setting modules |
Communication: | Direct control via keyboard or mouse, or via remote host (RS232/Ethernet/ modem), or via TCP/IP data exchange protocols available on demand |