Product Details:
Automation Grade | Automatic |
Size selective inlets | PM 10 Impactor and WINS Impactor for PM 2.5 conform to USEPA design |
Flow Rate: | 1 m3/hr maintained by microprocessor based electronic controller Auto shut-off of sampler if flow rate drops by more than 10% from designed value of 16.7 LPM |
Vacuum Pump: | Oil Free, non-pulsating pump driven by induction motor for stable flow rate |
Power requirement: | Nominal 220 V, Single Phase, 50 Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Automatic Sampling: | In-built system to control start and stop times of sampler |
Volumetric flow rate compensation: | Performed automatically by the system using Sensors for Ambient Temp., Barometric Pressure and Filter Pressure |
Elapsed time indicator: | Real Time clock based. Operating time for each sample in hours and minutes is recorded |
Flow recorder: | USB flash memory based system records flow rate, volume of air sampled, air temperature, filter temperature, filter pressure and barometric pressure |
Volume Totalizer: | MCU unit totalizes and displays volume of air sampled |
Display: | Large 40 Ch. X 4 line back lit LCD provides all system parameters at a glance |
Software and reporting: | PC based software provides intelligent report of all system parameters recorded during. Summary of run time parameters provided at end of sample duration |
Additional Information:
Size Selective inlets: | Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate: | Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system |
Vacuum Pump: | Oil Free, non-pulsating pump driven by induction motor for stable flow rate |
Power requirement: | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Sample Volume: | Dry Gas meter records the total air volume sampled |
Filter: | Filter holder designed to accept any standard 47 mm diameter filter media |
Additional Information:
Size Selective inlets: | Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate: | Constant sampling rate of 1 m3/hr maintained by critical orifice system and displayed on a rotameter requires no maintenance |
Vacuum Pump: | Oil Free, light weight pump driven by brushless induction motor |
Power requirement: | Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Size & Weight: | Compact & Light: Single unit compact cabinet made of Aluminum is light and robust |
Warranty: | One year |
Time totalizer: | Records the actual time duration of each sample |
Provision to attach Gaseous Sampler: | In-built valve and piping for use of a gaseous sampling attachment for monitoring SO2, NOx, NH3, Ozone etc |
Additional Information:
Size Selective inlets: | Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor |
Flow Rate: | 1 m3/hr controlled by mass flow controller |
Vacuum Pump: | Oil Free, non-pulsating pump driven by induction motor for stable flow rate |
Power requirement: | Nominal 220 V, Single Phase, 50 Hz AC mains supply. For proper operation and safety a good earth connection is mandatory |
Filter Media: | Filter holder designed to accept any standard 47 mm diameter filter media |
Sample Volume: | Dry Gas meter records the total air volume sampled |
Elapsed time indicator: | Real Time clock records the operating time for each sample |
Flow recorder: | Digital Micro-controller based system records flow rate, volume of air sampled, air temperature and filter temperature in non-volatile flash memory |
Calibration unit: | Leak Check & Flow rate measurement adapter |